Welcome to our new site, if you can’t find what you’re looking for please get in touch via our contact us page.
Welcome to our new site, if you can’t find what you’re looking for please get in touch via our contact us page.
Carbon fibre thread evaporation module with unique thread tracking system, allowing up to 50 coatings without having to break vacuum and replenish the carbon source. Controlled, automatic pulse evaporation modes give optimal coating control and film quality. Easy-fit electrical and pneumatic interface to CCU-010 LV and CCU-010 HV platforms. Includes one 300015 carbon thread on coil 2m.
Carbon fibre thread evaporation module with unique thread tracking system, allowing up to 50 coatings without having to break vacuum and replenish the carbon source. Controlled, automatic pulse evaporation modes give optimal coating control and film quality. Easy-fit electrical and pneumatic interface to CCU-010 LV and CCU-010 HV platforms. Includes one 300015 carbon thread on coil 2m.
Consisting of base plate for connection to the tilt and height adjustable specimen table of the CCU-010 base unit. Specimen holders for six large (Ø 25.4mm) or six small (Ø12.7mm) SEM pin stubs. DC micro-motor for rotation and planetary movement, quartz sensor (centre), speed control: 0-100%, rotation: 0-20rpm approximately, planets: 0-65rpm approximately
Consisting of base plate for connection to the tilt and height adjustable specimen table of the CCU-010 base unit. Specimen holders for six large (Ø 25.4mm) or six small (Ø12.7mm) SEM pin stubs. DC micro-motor for rotation and planetary movement, quartz sensor (centre), speed control: 0-100%, rotation: 0-20rpm approximately, planets: 0-65rpm approximately
Edwards RV3 Two stage rotary vaccum pump 115/230V- 1-ph- 50/60Hz. Factory set to 230V for Europe• Speed (Pneurop 6602) 50 Hz: 3.3 m3h1 / 2 ft3min1 60Hz: 3.9 m3h1/ 2.3 ft3min1• Ultimate pressure 2.0 x 103mbar / 1.5 x 103 Torr• Inlet flange: NW25 / exhaust flange: NW25• Supplied with: 1 litre of Ultragrade 19 oil-inlet filter and O-ring• EMF10 (A46226000) exhaust oil mist filter recommended • Includes – A50505000UK/Ireland 2m mains lead
Edwards RV3 Two stage rotary vaccum pump 115/230V- 1-ph- 50/60Hz. Factory set to 230V for Europe• Speed (Pneurop 6602) 50 Hz: 3.3 m3h1 / 2 ft3min1 60Hz: 3.9 m3h1/ 2.3 ft3min1• Ultimate pressure 2.0 x 103mbar / 1.5 x 103 Torr• Inlet flange: NW25 / exhaust flange: NW25• Supplied with: 1 litre of Ultragrade 19 oil-inlet filter and O-ring• EMF10 (A46226000) exhaust oil mist filter recommended • Includes – A50505000UK/Ireland 2m mains lead
ST-010 specimen stage for microscopy slides. Comprises base plate connected to the tilt and height adjustable specimen table of the CCU-010 base unit. For two microscopy slides 76 x 26mm or one slide 76 x 52mm. Can also be used for coverslips. Twelve M2 threaded holes for S-clips. Two FTM quartz crystal positions (centre and edge). Six mounting clips M2 included.
ST-010 specimen stage for microscopy slides. Comprises base plate connected to the tilt and height adjustable specimen table of the CCU-010 base unit. For two microscopy slides 76 x 26mm or one slide 76 x 52mm. Can also be used for coverslips. Twelve M2 threaded holes for S-clips. Two FTM quartz crystal positions (centre and edge). Six mounting clips M2 included.