Welcome to our new site, if you can’t find what you’re looking for please get in touch via our contact us page.
EBSD 70° pre-tilt split mount holder for cross sections
EM-Tec P77 EBSD 70° pre-tilt split-mount sample holder for cross sections up to 8mm – pin (each)
£62.11
Related products
-
CCU-010 LV (standard vacuum)
Safematic CCU-010 LV compact, fully automatic standard vacuum coating system. Including dual-position terminating film thickness monitoring system. Please note that for a complete working system the CCU-010LV requires the following: backing rotary vacuum pump (A65201903), oil mist filter (A46226000) and pumping hose (C10514297). Select coating head option SP-010 (sputteringing), CT-010 (carbon evaporation) or both. Select required sputtering target(s). Detailed description: • glass work chamber- 104 mm Ø x 106 mm (DN 100 ISO-KF compatible)• implosion guard and safety monitoring• table (Ø 80 mm) – tilt and height adjustable • multi-sample holder for 20 standard (13 mm) pin stubs to meet most requirements• film thickness monitor (FTM) based on a quartz crystal oscillator- usable in two positions (centre/edge)• full range power supply (90-260VAC- 50/60Hz)• coating process head interface (gas and electric) including automatic detection• 5.7“ TFT touch display• recipe-driven user interface for guaranteed reproducible results• storage / view of the last ten coating processes• automatic vent of the system when power failures – prevents backstreaming of oil from the rotary pump• intuitive operator’s software• graphic display of process data with Windows-based software Coating LAB (option)• flange connection (KF25) for connection of an external roughing pump• external alarm connector• USB service interface for easy analysis and software upgrades• automatic valve control for two process gases and venting• operating manual
SKU: 100000Price On Request £0.00 Add to basketAdd to QuoteWithin your QuoteAdd to QuoteCCU-010 LV (standard vacuum)
Safematic CCU-010 LV compact, fully automatic standard vacuum coating system. Including dual-position terminating film thickness monitoring system. Please note that for a complete working system the CCU-010LV requires the following: backing rotary vacuum pump (A65201903), oil mist filter (A46226000) and pumping hose (C10514297). Select coating head option SP-010 (sputteringing), CT-010 (carbon evaporation) or both. Select required sputtering target(s). Detailed description: • glass work chamber- 104 mm Ø x 106 mm (DN 100 ISO-KF compatible)• implosion guard and safety monitoring• table (Ø 80 mm) – tilt and height adjustable • multi-sample holder for 20 standard (13 mm) pin stubs to meet most requirements• film thickness monitor (FTM) based on a quartz crystal oscillator- usable in two positions (centre/edge)• full range power supply (90-260VAC- 50/60Hz)• coating process head interface (gas and electric) including automatic detection• 5.7“ TFT touch display• recipe-driven user interface for guaranteed reproducible results• storage / view of the last ten coating processes• automatic vent of the system when power failures – prevents backstreaming of oil from the rotary pump• intuitive operator’s software• graphic display of process data with Windows-based software Coating LAB (option)• flange connection (KF25) for connection of an external roughing pump• external alarm connector• USB service interface for easy analysis and software upgrades• automatic valve control for two process gases and venting• operating manual
£0.00Price On Request -
Edwards RV3 rotary vacuum pump (including Ultragrade oil) with 2m UK mains lead
Edwards RV3 Two stage rotary vaccum pump 115/230V- 1-ph- 50/60Hz. Factory set to 230V for Europe• Speed (Pneurop 6602) 50 Hz: 3.3 m3h1 / 2 ft3min1 60Hz: 3.9 m3h1/ 2.3 ft3min1• Ultimate pressure 2.0 x 103mbar / 1.5 x 103 Torr• Inlet flange: NW25 / exhaust flange: NW25• Supplied with: 1 litre of Ultragrade 19 oil-inlet filter and O-ring• EMF10 (A46226000) exhaust oil mist filter recommended • Includes – A50505000UK/Ireland 2m mains lead
SKU: A65201903Price On Request £0.00 Add to basketAdd to QuoteWithin your QuoteAdd to QuoteEdwards RV3 rotary vacuum pump (including Ultragrade oil) with 2m UK mains lead
Edwards RV3 Two stage rotary vaccum pump 115/230V- 1-ph- 50/60Hz. Factory set to 230V for Europe• Speed (Pneurop 6602) 50 Hz: 3.3 m3h1 / 2 ft3min1 60Hz: 3.9 m3h1/ 2.3 ft3min1• Ultimate pressure 2.0 x 103mbar / 1.5 x 103 Torr• Inlet flange: NW25 / exhaust flange: NW25• Supplied with: 1 litre of Ultragrade 19 oil-inlet filter and O-ring• EMF10 (A46226000) exhaust oil mist filter recommended • Includes – A50505000UK/Ireland 2m mains lead
£0.00Price On Request -
EMF10 mist filter
Edwards EMF10 oil mist filter suitable for use with an RV3 pump. Supplied with NW25 clamp, centering ring and O- ring- NW25 to 3/4 inch BSP adaptor.
SKU: A46226000£271.60 Add to basketAdd to QuoteWithin your QuoteAdd to QuoteEMF10 mist filter
Edwards EMF10 oil mist filter suitable for use with an RV3 pump. Supplied with NW25 clamp, centering ring and O- ring- NW25 to 3/4 inch BSP adaptor.
£271.60 -
Silencer for nXDS and XDS5/10
Silencer for nXDS and XDS10i scroll pumps (not connected to a house exhaust system). Silencer also offers exhaust filtration.
SKU: A50597000£230.53 Add to basketAdd to QuoteWithin your QuoteAdd to QuoteSilencer for nXDS and XDS5/10
Silencer for nXDS and XDS10i scroll pumps (not connected to a house exhaust system). Silencer also offers exhaust filtration.
£230.53