CondoCell

Transportable Hypoxia Containment vessel. Delivering luxury accommodation for cells!

THE CONDOCELL SYSTEM
Each of our unique solutions may be utilised separately or in conjunction with one another to improve results, based on the needs of your research.

CondoCell captures and maintains key environmental conditions your cells require for survival when threatened by ambient conditions from outside of the culture environment (e.g. incubator door openings).

When used in conjunction with a hypoxic incubator and/or a physiological cell culture workstation CondoCell can provide contained environmental control over the entire cell culture process and analysis (e.g. imaging), never exposing your cells to oxidative stress from the outside. An added benefit of this type of containment is minimal cross contamination where incubators or workstations are used as a shared facility. With CondoCell you can be confident that your work will never be compromised by the limitation of your existing equipment, resulting in more, better and happier cells.

With ConoCell, you can be confident that your work will never be compromised by the limitation of your existing equipment, resulting in more, better and happier cells! Where data is King, the CondoCell provides a consistent environment, maintaining optimal growth conditions, leading to more meaningful results.

Atmosphere Circulation Unit (ACU) to be used with an incubator.
Rapid Purge Unit (RPU) for fast adjustment of O2 within the CondoCell.
(see details below)

£0.00

Contaminant-free and controlled, air-tight culture vessel

 

  • Mass: 1.6kg
  • 1x T75 Flask
  • Up to 6x T25 Flask
  • Up to 3x 90mm Cell Culture Dish
  • Up to 3 x 96 Well Plate
  • Up to 2x 12 Well Plate [based on typical culturing vessels]
  • External dimensions: 65 x 150 x 278 mm (H x W x D)Internal dimensions: 53 x 105 x 180mm (H x W x D)

 

RETENTION TIME
Temperature (within 2°C) 20 Min
Humidity (within 2%) 60+ Min
Co2 (within 2%) 30 Min
O2 (within 0.2%) 30 Min

Breathes and distributes the culture environment to the CondoCell

 

  • Mass: 1.1kg
  • Door timer delay: 0-60 minutes
  • Mains Power: 8W
  • Incubator Door Sensors: up to 4
  • Mains Supply: 100-240 V ac 50/60Hz
  • Flow rate: 20mL/minute
  • Volume exchange rate: 1 exchange per hour
  • Dimensions: 60 x 238 x 228 mm (H x W x D)

Reduces oxygen concentration in a CondoCell

 

  • Mass: 600g
  • Mains Power: 3W
  • Mains Supply: 100-240 V AC 50/60Hz
  • Reduce to 1% O₂ in less than 1 minute
  • Dimensions: 125 x 170 x 115mm (H x W x D)